Specifications
· Operating Pressure:350BAR
· Flow:60L/min
· Internal Leakage:0.7ml/min.max.to 80% of norminal setting
· Temperature:-40°C to +120°(-40°F to+250°F)
· Cavity: T-11A
· Fluids: Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Although this is a zero pilot flow valve, port 3 (drain) must be
connected to maintain a pressure reference in the control chamber.
If port 3 is blocked, reciprocating seal weepage will cause the valve
to malfunction
· Pressure at port 3 is directly additive to the valve setting at a 1:1
ratio and should not exceed 5000 psi (350 bar)
Operation
Direct-acting sequence Valve will supply a secondary circuit with flow once
the pressure at the inlet (port 1) has exceeded the valve setting. The
pressure setting of a sequence valve controls the pressure at port 1 relative
to the pressure at the drain (port 3).