Specifications
· Operating Pressure:350BAR
· Flow:60L/min
· Pliot Ratio:3:1
· Internal Leakage:0.07ml/min.max.at operating pressure
· Temperature:-40°C to +120°(-40°F to+250°F)
· Cavity: T-11A
· Fluids:Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Provides hose break protection, prevents loads from drifting and
positively locks pressurized loads.
· Extremely low leakage. The seat and poppet are heat treated for
long life. If the load drifts due to the valve, the seat has probably
been damaged by contamination and the valve should be replaced.
· Standard unsealed pilot allows air trapped in the pilot line to be
purged from the circuit.
Operation
This valve is a pilot to open check valve. It has a non-sealed pilot, a steel
seat, and is non-vented. It allows free flow from the valve (port 2) to the load
(port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3)
will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to
open the valve is directly proportional to the load pressure at port 1.
Pressure at port 2 directly opposes pilot pressure.