Specifications
· Operating Pressure:240BAR
· Flow:23L/min
· Internal Leakage:164ml/min.max.at operating pressure
· Temperature:-40°C to +120°(-40°F to+250°F)
· Cavity:10-4
· Fluids:Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Hardened,precision ground parts for durability
· Industry common cavity
· Efficient wet-armature construction
· Continuous-duty solenoid
· Compact size
Operation
When de-energized, the valve blocks all ports.
When coil S1 is energized, flow is allowed from ③ to ④, and
from ② to ①.
When coil S2 is energized, flow is allowed from ③ to ②, and
from ④ to ①.