Specifications
· Operating Pressure:210BAR
· Flow:30L/min
· Internal Leakage:82ml/min.max.at operating pressure
· Temperature:-30°C to +120°C(-22°F to+250°F)
· Cavity:TS-01
· Fluids:Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Hardened,precision ground parts for durability
· Industry common cavity
· Efficient wet-armature construction
· Continuous-duty solenoid
· Compact size
Operation
When energized, the valve allows flow from port ② to port ① or from
port ① to port ② free mobility , while blocking flow at port ③;
When de-energized, the valve's spool shifts open from port ③ to port
① or from port ① to port ③ , while blocking flow at port ② .