Specifications
· Operating Pressure:250BAR
· Flow:0.4- 7.5L/min
· Flow Tolerances:0.2 to 1.8lpm.settings±15%
1.9 to 7.5lpm.settings±10%
·Temperature:-30°C to +120°C(-22°F to+250°F)
· Cavity:08-2
· Fluids:Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Hardened,precision ground parts for durability
· Industry common cavity
· Compact size
· Adjustment may be locked in place.
· Adjustment will not screw out of the valve body
Operation
The valve maintains a constant flow rate out of ② regardless of load pressure changes in the circuit downstream of ②.The fixed control orifice is factory preset to customer flow specification.The valve begins to respond to load changes when the flow through the valve creates a pressure differential across the control orifice greater than 5.5 bar, with accurate flow maintenance from 7.6 to 240 bar. Reverse flow( ② to ① ) returns through the control orifice and is non-compensated.