Specifications
· Operating Pressure:350BAR
· Flow:60L/min
· Response Time - Typical:2ms
· Internal Leakage:10drop/min.max.to 80% of norminal setting
· Temperature:-30°C to +120°C(-22°F to+250°F)
· Cavity:T-13A
· Fluids:Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
· Approximately 1 drop (0,07 cc) of fluid will pass into the vented
spring chamber every 4000 cycles.
· Atmospherically referenced Valve should only be used where it is
impossible have a drain connection. Over time, the atmospherically
referenced Valve may leak externally or allow moisture into the
spring chamber.
Operation
Atmospherically referenced, direct-acting sequence Valve with reverse-
flow check will supply a secondary circuit with flow once the pressure at the
inlet (port 1) has exceeded the valve setting. Additionally, these Valve
incorporate an integral check valve to provide reverse flow from port 2
(sequence) to port 1 (inlet). The pressure setting of this sequence valve
controls the pressure at port 1 relative to the atmospheric vent.