1. Metrology - Laboratory
  2. Metrology and Test Equipment
  3. Climate chamber
  4. Wenzhou Tripod Instrument Manufacturing Co.,Ltd.

Climate chamber YGDW
humiditytemperaturemodular

climate chamber
climate chamber
climate chamber
climate chamber
climate chamber
climate chamber
Add to favorites
Compare this product
 

Characteristics

Type
climatic
Controlled parameter
humidity, temperature
Configuration
modular
Other characteristics
vacuum, low-temperature, alternating, for high temperatures
Capacity

100 l
(26 gal)

Temperature

Max.: 30 °C
(86 °F)

Min.: 10 °C
(50 °F)

Length

500 mm
(19.69 in)

Width

500 mm
(19.7 in)

Depth

400 mm
(16 in)

Description

The temperature controller of the high and low temperature alternating heat and humidity test chamber adopts the TH7110 series wide-screen panel LCD programmable temperature controller, which can be operated at a fixed value or a program, and the operation is simple and convenient. The refrigeration unit adopts French Taikang unit. The test box is equipped with a vacuum observation window with electrothermal coating, which can effectively solve the problem of condensation in the observation window. The test box adopts the overall integrated assembly structure, and the appearance is beautiful and elegant. Main purpose and scope of application The high and low temperature alternating humidity and heat test chamber is mainly used to test the temperature and humidity stress of the test piece, and can be used in aerospace, aviation, electronics, metallurgy, petroleum, chemical industry and other industries. Basis and use standard The design and manufacture of the test box meet the following test standards and methods GB2423.1-89 Test A Low temperature test method GB2423.2-89 Test A High temperature test method GB / T2423.3-93 Test method for Ca constant humidity and heat GB / T2423.4-93 Test Db alternating damp heat test method GB2423.34-86 Test Z / AD temperature and humidity combined cycle test method GJB150.3.4.9-89 High temperature test, low temperature test, damp heat test method GB10586-89 Technical Conditions of Damp Heat Test Chamber GB10592-89 high and low temperature test chamber technical conditions 2. 【Technical Parameters】 Temperature range: -40 ~ + 150 ℃ Studio size: 400 × 500 × 500 (mm) (depth × width × height)

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.