Water chiller LX
airindustrial

Water chiller - LX - Wuxi Guanya Temperature Refrigeration Technology Co. Ltd.. - air / industrial
Water chiller - LX - Wuxi Guanya Temperature Refrigeration Technology Co. Ltd.. - air / industrial
Water chiller - LX - Wuxi Guanya Temperature Refrigeration Technology Co. Ltd.. - air / industrial - image - 2
Water chiller - LX - Wuxi Guanya Temperature Refrigeration Technology Co. Ltd.. - air / industrial - image - 3
Water chiller - LX - Wuxi Guanya Temperature Refrigeration Technology Co. Ltd.. - air / industrial - image - 4
Add to favorites
Compare this product
 

Characteristics

Material
water, air
Applications
industrial
Power

Max.: 26.5 kW

Min.: 1 kW

Maximum temperature

Max.: 30 °C
(86 °F)

Min.: -15 °C
(5 °F)

Flow rate

20 l/min, 35 l/min, 75 l/min
(5.283 us gal/min, 9.246 us gal/min, 19.813 us gal/min)

Pressure

1.5 bar, 2.5 bar
(21.756 psi, 36.259 psi)

Description

Product Advantages: 1. The temperature of heat transfer fluid can be adjustable; 2. Adopt ASPERA,DANFOSS,MANEUROP,COPELAND etc. Brand compressor.Stable performance and can work continuously; 3. Use hot gas bypass, save energy and improve the control precision; 4. A variety of fault alarm (overtemperature alarm, high-pressure alarm, sensor alarm, compressor overheat alarm); 5. Power on delay protection;All parts are safety grounding. The outdoor installation of air-cooled chillers make it easy to be affected by outdoor sunlight, and the ventilation and the environment and space has a direct impact on the cooling effect of the chiller. The common failure and processing method are as follows: (1) Frequent start and stop of the compressor: there may be too much or too little refrigerant, resulting in pressure protection switch action which is resulted from too high exhaust pressure or too low suction pressure, and also poor water system circulation make sevaporator surface frost. Method: When the refrigerant is too much, the extra can be released at the vent. If there is a shortage, check whether there are leaks of the fluorine and fill the refrigerant. If the water circulation system is blocked or stored in the air, you should exhaust; if water circulation too small, utilize the open refrigeration water circulation system. (2) Noisy compressor when running: check whether the expansion valve fails, the temperature package discharges the suction pipe from the compressor, which causes the liquid refrigerant return to the compressor. -25℃~30℃
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.