40KHZ Frequency Ultrasonic Distance Sensor 50mm - 1000mm Detection Range
Description of Sensor Functions
Adjusting the switching points and the analog output.
The switch output type and analog output type sensor can be programed as the user want.
There is 8 types of output functions can be programed.
All the teach routine as follows,
step 1 teach one point with the related teach in condition(High level voltage or GND). step 2 choose a different distance(not the same with step1) point and a different teach in condition(not same with the step1). The program routine must be finished during the blue led flashing, the default value will be efficient if the not.
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - UB or + UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whether the sensor has recognized the target during the TEACH-IN procedure. Switching point A1 is taught with - UB, A2 with +UB. Five different output functions can be set.
1. Window mode normally-open and liner mode positive slope output function.
2. Window mode normally-closed and liner mode negative slope output function.
3. Single switching point, normally-open function.
4. Single switching point, normally-closed function.
5. Single switch point with hysteresis gap normally-open function.
6. Single switch point with hysteresis gap normally-closed function.
7. Detection of object presence-normal open function.
8. Detection of object presence-closed open function.