Our 80G frequency modulated radar level transmitter measures liquid level and material level, non-contact level measurement, strong anti-interference ability, can overcome the influence of steam, foam and stirring on the measurement, and accurately measure various small-range storage tanks and reactors The liquid level.
Feature
On-site working conditions
The tested device is a refined evaporator, which evaporates the water content in the medium to obtain ethanol with higher purity, multi-layer stirring, and 5-6cm foam.
Remarks: The liquid level instrument used before is a double flange differential pressure liquid level transmitter, and the measurement effect is not satisfactory.
Measurement process
This is an improvement of the measurement scheme. Because the installation port of the reactor is limited and the installation port is inclined and non-vertical, the radar level gauge needs to be installed vertically on the top to achieve the best measurement results. At the initial installation, although it was installed diagonally, the 80G FM radar level gauge has a relatively small launch angle, and the signal is not affected by the stirring blade. After debugging, the level can be measured.