sensors are intended for monitoring UV lamps in water/air purification and disinfection systems
detecting relative UV irradiance values
UV values are indicated in "%" or via "traffic light" with the appropriate UV-monitor
UV-sensors simply consists of a silicon carbide (SiC) diode without any internal electronic to allow high quality cost efficient projects
required external amplification is be maintained using ZED UV Monitors or ZED signal converters
depending on UV monitor type the sensitivity adjustment according to the UV lamp output is performed automatically during initial setup or manually via potentiometer
due to the low silicon carbide diode (SiC) output signal the max. recommended cable length is 3m in environments with low interferences
types with additional UV-C filter elements are available