Primary current: 4 A
Operating temperature: -40 °C - 85 °C
Plug-in connector, 5-pin, connector angled M12, A-coded, screw connection, material threaded ring: CuZn nickel-plated, outer cable diameter: 4-6mm Environmental data Overvoltage category - II Pollution ...
Impedance: 135 Ohm - 165 Ohm
Primary current: 30 mA
Voltage: 4.75 V - 5.25 V
The bus connector EasyConn PB is used for the connection of PROFIBUS participants to the bus line. The fully visible diagnostic LEDs facilitate the installation considerably. Users can immediately check the status of ...
Voltage: 24 V
Mating connector, connector 7-pole (6 + PE) EN 175301-804 For valves with round connector. OEM accessories. Industrial use. Electrical connector - Round connector ...
Bosch Rexroth - Industrial Hydraulics
... form a perfect match. This portfolio ranges from sensor cables to field connectors, junction blocks, sensor-actuator splitters, sensor-actuator receptacles, and data connectors. Whether you are at ...
Operating temperature: 30 °F - 230 °F
The MCQ quick connects features brass body, hard drawn brass check valve system, seals Buna N compound and works in air medium at 0 to 300 psig pressure with 5.8 scfm@100psig air flow. They work at -30 F to 230 F.
Primary current: 0.5 A - 3 A
Voltage: 250 V
• Electric connection module. • 32 electrical connection. • Feeler pin with self-clearing heads. • Output: four 8-pole cable x 0.14 mm². • The two parts are supplied separately: RMAQC – robot side; RMBQC - frame side. • Availability ...
• Co-moulded or field-wireable connectors for the connection of sensors and transducers. • Many solutions available with both straight and angled cable outlet. • Solutions with PVC and PUR cable.
Primary current: 3 A
Voltage: 50 V
Pitch: 1, 2.5, 2.2 mm
... save costs and ensures reliable production. The connector's double-clip structure (metal clip contact structure) ensures high resistance to shock and vibration at temperatures up to 125°C. The connector's ...
Panasonic Electric Works Europe
The RF circuit and ANT characteristics can be measured by mounting in an RF transmission line. The internally built-in mechanical switch separates the RF circuit and ANT circuit, so that the circuit can be measured without any mutual ...
Operating temperature: 0 °C - 425 °C
... several varieties of thermocouple connectors and systems including: standard thermocouple connectors, quick-attach thermocouple, connectors, high temperature ...
Primary current: 1.5 A - 13 A
Voltage: 30 V - 600 V
... photoelectric sensors, and other field devices. Cables can be 22 AWG or 18 AWG, shielded or unshielded with straight or right-angled connectors. Special coiled cables are also available for applications involving moving ...
High-quality accessories Developed for our products Aligned to our products Originals from the manufacturer IP65 socket devices or IP54 rubber protective caps for increased protection Simple installation with plug-in ...
SUCO Robert Scheuffele GmbH & Co. KG
Rohde offers tubular connectors RV that are at par with the standards of DIN 1725. These tubular connectors feature a variety of surface treatments including powder coatings, high-gloss polishes, drum ...
Voltage: 250 V
Operating temperature: -25 °C - 80 °C
... Matt nickel-plated zinc Cable length - 2 m Cable color - black Wire cross-section - 0.34 mm2 Product Range - Cable connector weld immune
CONTRINEX
A fibre interconnect is needed to connect one fibre to another. They can be useful for coupling patch cords to fibre-optic probes and other devices, or for any multiple-fibre application where coupling of standard optical fibres and accessories ...
M12 connector: . Straight connector, ref. CD M12. . Elbow connector, ref. CC M12. M8 connector: . Straight connector, ref. CD M8. . Elbow connector, ...
... fastening of 18ø photocells or proximity sensors;suitable for applications exposed to accidental impact. State of supply connector in aluminium alloy UNI 5076, 1 UNI 5931 socket head screw and 1 UNI 5588 hexagon nut, ...
... fastening of sensors or reflectors with clip pin, suitable for applications exposed to accidental impact. State of supply Connector in aluminium alloy UNI 5076, 1 UNI 5931 socket head screw and 1 UNI 5588 hexagon nut, ...
... possibility of adjustment) or reflectors with clip pin, suitable for applications exposed to accidental impact. State of supply connector in aluminium alloy UNI 5076, 1 UNI 5931 socket head screw and 1 UNI 5588 hexagon ...
The EVS connectors are used to connect the intrinsically safe circuits of the SYMEGA series grounding monitoring systems with their peripherals (spiral grounding cables, grounding clamps). These connectors ...
... terminals. They all have a tin-plated red finish and are available in round or flat format. Section: from 0,25 mm2 FLEXIBLE CONNECTORS WITH TERMINALS AVAILABLE Contact our sales department for more information about ...
Operating temperature: 0 °C - 50 °C
This system allows the installation of a series of 1/8 solenoid valves with different functions: 5 / 2 monostable 5 / 2 bistable and 5 / 3, through a a printed circuit board inserted in an aluminum shell with a female connection SUB-D ...
Voltage: 24 V
Airwork introduce the multipolar connection system for VA series solenoid valves. This accessory allows the possibility to install a series of valves electrically controlled on an aluminium sub-base. In this way, you can control them ...
Primary current: 16 A
Voltage: 48 V
Multi-X Electric Connector Kits Multi-X can be fitted with an electric connector kit on both the male and the female plate.
CEJN
Elevate your vacuum system performance to new heights with PEEK UHV connectors. Crafted from high-performance PEEK material, these connectors offer unparalleled durability, corrosion resistance, and leak-free ...
... superior performance with PEEK Fluid Connectors, designed for demanding environments. Their exceptional chemical resistance and durability make them perfect for HPLC and other analytical applications. PEEK Fluid Connectors ...
Data rate: 125 kB/s - 1,000 kB/s
CANCrocodile allows safe data reading from vehicle's CANbus. CANCrocodile has no direct electrical contact with CANbus, because the device reads data through the insulation of wires. Thus, CANbus integrity is not violated and warranty ...
Data rate: 0 kB/s - 0 kB/s
1708Crocodile contactless reader is designed for safe reception of vehicle operation data from J1708 bus (SAE J1587). The reader functions without direct electric contact with the bus wires. The mounting of the device is done by putting ...
Data rate: 125 kB/s - 1,000 kB/s
CANCrocoLITE — is a tool for telematics systems used for data reading from on-board CAN bus of personal cars and light commercial vehicles without interference in integrity of electronic circuits. CANCrocoLITE is used within telematics ...
M12, 4 pin female Code A right angled connector. Field connectable with screw terminals, no soldering required. Suitable for cable diameter 4.0mm - 8.0mm. Used on PCH, SLSP and HPT02.
M12, 4 pin female Code A straight connector. Field connectible with screw terminals, no soldering required. Suitable for cable diameter 4.0mm - 8.0mm. Used on LPCH, SLSP and HPT02.
Cables & Connectors for Fixed Vibration Systems CEMB Monitoring Vibration Systems (Sensors and Transducers) can be supplied stand alone and assembled on field by customer They also can be supplied by CEMB complete ...
Impedance: 0 Ohm - 4 Ohm
Primary current: 10, 16 A
Voltage: 24, 115, 230 V
Series of connectors in different sizes for coils. In the standard version they are provided with fixing screw and NBR profiled seal. Yellow LED as standard in the provided versions. Cabled versions available. ATEX ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining