- Detection - Measurement >
- Electrical Measurements >
- Calibrator >
- Fluke
Fluke calibrators
Vibration Calibrators Application • Rapid and easy calibration of vibration transducers for acceleration, velocity and displacement • Calibration and fault detection of vibration measuring systems • Calibration ...
Metra Mess- und Frequenztechnik in Radebeul e.K.
Pressure: -0.8 bar - 10 bar
... environments and simulates leaks in flow, independent of pressure and temperature influences. Use as a leak instrument calibrator and leak simulator • High accuracy and repeatability • Touchscreen display ...
innomatec
Calibration of force reference standards Reference standard measurement machine inspekt K 600kN Load cells, which are used for example in classic material testing machines, must be checked periodically for their measuring accuracy ...
Temperature: -40 °C - 125 °C
Pressure: 0 bar - 10 bar
Voltage: 24, 220 V
The gas density relay calibrator, a fully automatic intelligent SF6 gas density relay calibrator (including SF6 gas density relay calibrator and SF6/N2 gas density relay calibrator), ...
Temperature: -35 °C - 85 °C
The LaserTRACER-NG was developed for calibration, monitoring and accuracy enhancement of measuring machines and machine tools. It is a self-tracking laser interferometer that automatically tracks a reflector, and hence allows for the ...
Pressure: 800 mbar - 1,150,000 mbar
CO2 Zero Calibration Kit for the Guardian NG The Zero Calibration Kit acts as a convenient alternative to bottled gas for checking zero offsets and if necessary, zero calibration. It works by removing the CO2 from the air being drawn ...
Traceable sound level meter calibration for sound level meters, noise monitors, vibration meters and acoustic calibrators Guarantee the accuracy and reliability of your sound and vibration measurement instruments with ...
Cirrus Research
Portable, user friendly calibrator, ideal for checking sound level meters and dosimeters on the measurement site, or in the laboratory. It is designed especially to check class 2 dosimeters and sound level meters. Represents ...
Voltage: 9 V
Quickly and Easily Test/Calibrate Your Own: Micrometer “Clicker” Torque Wrenches Dial Type Torque Wrenches Torque Screwdrivers Electric Torque Screwdrivers Pneumatic Torque Screwdrivers DC Nutrunners Mount anywhere on a bench ...
Noise level: 94, 114 dB
... Conforms to ANSI S1.4-1984 and IEC942 1988 Class 2 standards for acoustical calibrators. Simply place the calibrator on to the digital sound meter’s microphone, turn on the calibrator, ...
XCal automates the maintenance and calibration process of rotating lasers with the help of Metor-RF laser receivers sending their readings to your Windows-PC via wireless transmission. With XCal you can easily determine and correct ...
Voltage: 30, 300, 750, 100, 10 V
KS833 Three-phase AC/DC/Harmonic Standard Source and Calibrator (0.05 class) Item No.: 202004 Open protocol for software self-programming. AC voltage sources: 3x900V@3x25VA, accuracy 0.05% AC current sources: 3x30A@3x25VA, ...
Kingsine Electric Automation Co., Ltd.
... are often exposed to hard working conditions, a performance check is recommended before every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 100 A with an accuracy better 1%. They qualify ...
FUNCTIONS ▪Setting standard sound level at 94 dB and 114 dB. ▪According Standard: ANSI S1.4-1984 and IEC 942 1988 Class 2. ▪½¡¨ microphone adapters provided. ▪Low battery indicator.
... very easy to utilize and it has multi function calibrator. The TechChek 830 sources and reads like a milliamp or voltage calibrator, as well as simulates and measures T/Cs & RTDs like a temperature calibrator. ...
ALTEK Industries Corp
HIGHLIGHTS AND FEATURES: 1. - Calibrate different types of torque tools, such as, Type-1 (Indicating) and Type-2 (Setting) as per ISO 6789:2017-2. o - Includes all indicating, settable, or fixed type of Torque Wrenches like Dial, Click, ...
multitektechnologies
Specifications and Accessories 515 Sound Level Calibrator * 1000 Hz +/- 1% * Distortion Less than 2% THD * 0 dB Reference Point for: A, B, C, D Weighting * 94 dBSPL = 1 Pa * Accuracy - Meets IEC60942:2003 ...
The PVC-500Portable Vibration Calibrator is an ideal tool for checking accelerometers, velocity transducers, and proximity probes over a wide operating frequency and amplitude range. The unit is a compact, and completely ...
Vibsens
The use of sound calibrators dates back to the days when it was easier to design a stable sound calibrator than a stable Sound Level Meter. Today, sound measuring instruments, in general, are as stable ...
Pressure: -1 bar - 250 bar
Modular built, automatic Pressure Calibrator ...MEASURE PRESSURE, VERY SIMPLE... TM40_web - Our modular built Pressure-Calibrator TM40 is unique in its conception. The device is built completely ...
Temperature: 0 °C - 50 °C
Pressure: 1.72 bar
The Environics® Series 6100 Computerized Multi-Gas Calibration System is a computer controlled, state-of-the-art instrument for dynamic multi-point gas calibration of ambient air analyzers. The Series 6100 automatically ...
Environics
The Dytran model 3120B is an accelerometer that is a double ended IEPE reference (comparison). It can be used with unknown acceleration, velocity and displacement sensors in order to measure their sensitivity and frequency response characteristics. ...
DYTRAN INSTRUMENTS
In combination with a PC, laptop or tablet PC the digital calibration and measurement unit (DCMU box) is an ideal solution for testing, documenting and calibrating sensors, especially incremental rotary encoders. The DCMU box has a modular ...
Temperature: 5 °C - 375 °C
Voltage: 220, 110 V
Temperature Calibrator, Tradinco Traqc-3 FM Are you looking for a precision field dry-block temperature calibrator? The Traqc-3 is extremely suitable for use in field applications. This light weight ...
Tradinco
Temperature: 0 °C - 50 °C
Voltage: 115 V - 230 V
ECOTECH Model H2S-1100 Hydrogen Sulfide Converter employs both catalytic and thermal principles to convert H2S to SO2. Converter efficiency is better than 95 % over a temperature range of 300 °C to 400 °C. (350 °C is the optimal temperature ...
Ecotech
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining