- Robotics - Automation - Industrial IT >
- Automation >
- Analog I/O >
- Gantner
Gantner analog I/O
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE High-accuracy digitization 24-bit ADC, 100 kHz sample rate per channel Status, trigger, tare, ...
Gantner Instruments
measuring half and full bridge, IEPE-sensor, voltage, current, quarter bridge with completion terminal voltage (±10 V) or current (0 - 20 mA), 100 kHz update rate High-accuracy digitization 19-bit SAR ADC, 100 kHz sample rate status, ...
Gantner Instruments
thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic linearization correction optimal position ...
Gantner Instruments
thermocouple (type K), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic linearization correction optimal position of the interpolation points adjusted ...
Gantner Instruments
Pt100, Pt1000, resistance 400 ohm / 4000 ohm , 2-, 3- or 4- wire connection High-precision temperature measurement max. measurement error 0.05°C, temperature drift 0.02 / 10K (for Pt100) High-accuracy digitization 24-bit ADC, ...
Gantner Instruments
RTD sensors, resistance 6500 Ω and 20000 Ω, 2-, 3- or 4-wire Low excitation current 7.5 µA effective, to minimize sensor self-heating errors Individual linearization of the sensor characteristics Sensor specific linearization ...
Gantner Instruments
strain gage and inductive half and full bridges, LVDT, RVDT quarter bridge with completion terminal DC and carrier frequency (CF) principle 2.5 and 5 VDC excitation, 2.5 and 5 VDCeff excitation carrier frequency, 600 Hz or 4.8 kHz ...
Gantner Instruments
voltage, current, resistance, potentiometer, RTD (Pt100 / Pt1000), thermocouple, strain gage High-accuracy digitization 24-bit ADC, 20 kHz sample rate per channel Signal conditioning linearization, filtering, average, scaling, ...
Gantner Instruments
differential voltage, current (with shunt resistor) status, trigger, tare, alarm, command High-accuracy digitization 24-bit ADC, 20 kHz sample rate per channel Signal conditioning linearization, filtering, average, scaling, ...
Gantner Instruments
2 DSUB9 input sockets Sensor supply galvanic isolated 6+2 Analog input channels AI1,AI2,AI3 differential /single-ended switchable in groups AI5,AI6,AI7 differential /single-ended switchable in groups AI4,AI8 single-ended ...
Gantner Instruments
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining