Voltage, current, resistance, potentiometer, RTD, thermocouple, strain gage (full-, half-, and quarter-bridge configuration), IEPE High-accuracy digitization 24-bit ADC, 100 kHz sample rate per channel 2 Digital inputs or outputs Status, ...
Gantner Instruments
measuring half and full bridge, IEPE-sensor, voltage, current, quarter bridge with completion terminal 1 Analog output channel voltage (±10 V) or current (0 to 20 mA), 100 kHz update rate High-accuracy digitization 19-bit SAR ADC ...
Gantner Instruments
thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic linearization correction optimal position of the ...
Gantner Instruments
Pt100, Pt1000, resistance 400 ohm / 4000 ohm , 2-, 3- or 4- wire connection High-precision temperature measurement max. measurement error 0.05°C, temperature drift 0.02 / 10K (for Pt100) High-accuracy digitization 24-bit ADC, 10 Hz ...
Gantner Instruments
RTD sensors, resistance 6500 Ω and 20000 Ω, 2-, 3- or 4-wire Low excitation current 7.5 µA effective, to minimize sensor self-heating errors Individual linearization of the sensor characteristics Sensor specific linearization by using ...
Gantner Instruments
thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection Automatic linearization correction optimal position of the ...
Gantner Instruments
voltage, current, resistance, potentiometer, RTD (Pt100 / Pt1000), thermocouple, strain gage High-accuracy digitization 24-bit ADC, 20 kHz sample rate per channel Signal conditioning linearization, filtering, average, scaling, min/max, ...
Gantner Instruments
... ±10 VDC, 20 kHz update rate per channel High-accuracy digitization 24-bit ADC, 20 kHz sample rate per channel 4 digital I/Os input: state, tare, memory reset, output: state, alarm, threshold Signal conditioning linearization, ...
Gantner Instruments
differential voltage, current (with shunt resistor) 2 Digital inputs and outputs status, trigger, tare, alarm, command High-accuracy digitization 24-bit ADC, 20 kHz sample rate per channel Signal conditioning linearization, filtering, ...
Gantner Instruments
differential voltage ±60 V, isolation voltage 500 VDC High accuracy digitalization 24 bit ADC, 20 kHz sample rate per channel 2 digital in and 2 digital outputs input: state, tare, memory reset, output: state, Alarm, threshold Signal ...
Gantner Instruments
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining