- Detection - Measurement >
- Flow, Pressure and Level Measurements >
- Modbus flow meter >
- Greyline Instruments
Greyline Instruments Modbus flow meters
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Process temperature: 180 °C
Process pressure: 10 bar - 100 bar
... that meets the needs. ProcessMaster FEP300 is a versatile, reasonably priced, most accurate flow meter tailored for all process industry applications. A flowmeter with base functionality, ...
ABB Measurement & Analytics

Mass flow rate: 0 kg/h - 250,000 kg/h
Process temperature: -50 °C - 205 °C
Process pressure: 0 bar - 60 bar
CoriolisMaster FCH400 series of compact Coriolis mass flowmeters for hygienic applications feature low pressure drop, high capacity, intuitive ABB common display, five modular I/Os and various communication ...
ABB Measurement & Analytics

Mass flow rate: 0 kg/h - 860,000 kg/h
Process temperature: -50 °C - 205 °C
... series of compact system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus communication and 2 digital outputs. With no up ...
ABB Measurement & Analytics

Volumetric flow rate: 0.005 l/min - 150 l/min
Precision: 0.5 %
The JUMO flowTRANS MAG H20 is an electromagnetic flowmeter for industrial automation. Its compact design allows it to fit into the smallest plants (dosing systems, apparatus cooling) and to measure conductive media with ...

Mass flow rate: 0 kg/h - 2,200,000 kg/h
Process temperature: -196 °C - 240 °C
Process pressure: 100 bar
... process safety – immune to fluctuating and harsh environments Fewer process measuring points – multivariable measurement (flow, density, temperature) Space-saving installation – no in-/outlet run needs Full access ...
Endress+Hauser AG

Process temperature: -40 °C - 60 °C
... gas flow meter is an advanced electronic meter for natural gas flow measurement, which adopts ultrasonic technology to maintain long-term accuracy without degradation. With ...

Volumetric flow rate: 0.1 l/min - 50 l/min
Process temperature: -10 °C - 50 °C
Process pressure: 1,000, 1,500 psi
... as well as other high purity gas applications. The base blocks of the Mass Flow Meters and Controllers have 1/4" face seal male (VCR) connections. Metal Sealed Mass Flow Meter/Controller ...
Bronkhorst

Volumetric flow rate: 0.4 m³/h - 11,000 m³/h
Process temperature: -10 °C - 70 °C
Process pressure: 100, 64, 40, 200, 400 bar
... standard Compact and competitive Mass Flow Meters for high gas flow rates For consumption measurement of high gas flow rates, customers often select volumetric ...
Bronkhorst

Volumetric flow rate: 0 l/min - 10,000 l/min
Process temperature: 0 °C - 50 °C
Process pressure: 20, 16, 7 bar
The digital MASS-STREAM™ series D-6300 & D-6400 work on the basis of direct through-flow measurement, following the constant temperature anemometer principle. - Applications Process gas measurement ...
Bronkhorst

Process temperature: 0 °C - 140 °C
Process pressure: 0 bar - 40 bar
Liquid flow meter OPTIFLUX 6000 Electromagnetic flowmeter for advanced hygienic applications * (±0.2%), for exact dosing or filling in the food sector * Meter size: ...
KROHNE Messtechnik GmbH

Process temperature: -40 °C - 120 °C
Process pressure: 0 bar - 40 bar
... / ASME Cl :300 * 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET The OPTIFLUX 7300 is a an electromagnetic flowmeter (EMF) for measuring very low conductivity liquids (≥0.05 μS/cm). The high-end ...
KROHNE Messtechnik GmbH

Process temperature: -40 °C - 93 °C
Process pressure: 350 bar
Coriolis mass flowmeter OPTIGAS 4010 Coriolis mass flowmeter for gas dispenser applications * High accuracy for CNG and LPG up to 70 kg/min / 155 lb/min * Thread: ...
KROHNE Messtechnik GmbH

Mass flow rate: 0 kg/h - 0.16 kg/h
Volumetric flow rate: 0 m³/s - 0 m³/s
Process temperature: 0 °C - 50 °C
... OLED display Digital or analog output; alarm and counter functions Features Clear indication in: - actual flow rate (bar graph and value) - desired flow units - type of gas - ...
Mass Flow ONLINE BV

Mass flow rate: 0 kg/h - 1.55 kg/h
Volumetric flow rate: 0 m³/s - 0.0003 m³/s
Process temperature: 0 °C - 50 °C
... OLED display Digital or analog output; alarm and counter functions Features Clear indication in: - actual flow rate (bar graph and value) - desired flow units - type of gas - ...
Mass Flow ONLINE BV

Mass flow rate: 0 kg/h - 15.5 kg/h
Volumetric flow rate: 0 m³/s - 0.0033 m³/s
Process temperature: 0 °C - 50 °C
... OLED display Digital or analog output; alarm and counter functions Features Clear indication in: - actual flow rate (bar graph and value) - desired flow units - type of gas - ...
Mass Flow ONLINE BV

Process temperature: -20 °C - 80 °C
Process pressure: 0 psi - 10 psi
Precision: 0.25 %
... Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring ...
Pulsar Measurement

Volumetric flow rate: 0.1 ft³/s - 40 ft³/s
Process temperature: -23 °C - 60 °C
Process pressure: 0 psi - 10 psi
Gaining flow measurement inside a pipe can sometimes be tricky. The DFM 6.1 Doppler Flow Meter works as a non-contacting, clamp-on flow meter to offer ...
Pulsar Measurement

Process temperature: -20 °C - 50 °C
... applications. Area-Velocity Measurement / Open Channel Flow Measurement with No Primary Measuring Device FlowCERT can be combined with a MicroFlow for velocity measurement. Or for area-velocity flow ...
Pulsar Measurement

Volumetric flow rate: 0 ft³/s - 0.3767 ft³/s
Process temperature: -50 °C - 85 °C
Process pressure: 0 psi - 300 psi
... withstand sustained vibration Confirm meter calibration without interrupting the process using continuous meter verification Perform easy repairs in the field without the need ...

Process temperature: -40 °C - 140 °C
Precision: 0.3, 0.5, 0.2 %
... product - Flow Product or component type - Magnetic flowmeter transmitter Device application - To measure the flow of pressure for liquid, gas, steam Market segment - Pharmaceutical Power Product ...

Process temperature: -20 °C - 80 °C
Precision: 1.5 %
... ultrasonic flowmeter M-Flow PW This ultrasonic portable flowmeter consists of a detector clamped on the pipe (DN25 to 1200 mm depending on detectors) and of a and of a digital converter ...

Process temperature: -20 °C - 50 °C
... 15 universal inputs max. 72 analogue inputs max. 72 digital inputs max. 36 TC inputs max. 18 RTD inputs max. 12 counter / flowmeter / ratemeter inputs max. mixed: analogue-NTC temperature mixed: ...

Process temperature: -20 °C - 50 °C
... 9 universal inputs max. 48 analogue inputs max. 48 digital inputs max. 24 TC inputs max. 12 RTD inputs max. 12 counter / flowmeter / ratemeter inputs max. 1 digital input 24V DC mixed: analogue-NTC ...

Process temperature: -20 °C - 50 °C
MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package stable firmware based on Linux 13 available input/output blocks colour LCD display 3,5" TFT, with touchscreen recording data with maximum speed ...

Process temperature: -10 °C - 60 °C
Precision: 3, 0.5, 1 %
Repeatibility: 0.15 %
... Description The ultrasonic flow meter clamp-on for fixed installation IFX-F100, flow meters, energy meters, ultrasonic flowmeters, and industrial ...
ISOIL Industria Spa

Process temperature: -30 °C - 130 °C
Precision: 1, 3, 0.5 %
Repeatibility: 0.15 %
... communication protocols such as the Modbus. Description The portable clamp-on flow meter IFX-P210, flow meters, energy meters, ...
ISOIL Industria Spa

Process temperature: -40 °C - 150 °C
Precision: 1 %
Repeatibility: 0.25 %
... Description The portable clamp-on flow meter for fixed installation IFX-f161, flow meters, energy meters, ultrasonic flowmeters, and industrial automation ...
ISOIL Industria Spa

Volumetric flow rate: 0 l/min - 20 l/min
The new mass flow meters and mass flow controllers from Angst+Pfister Sensors and Power are based on the latest generation of MEMS sensor elements. In addition to the outstanding accuracy ...

Process temperature: -18 °C - 121 °C
Process pressure: 10, 34 bar
Precision: 0.5, 1, 2 %
... compact, low cost solution for accurate, repeatable flow measurement of biogas, digester gas, landfill gas, methane and natural gas as well as air, compressed air or nitrogen. This insertion-style flow ...
FCI Fluid Components International

Volumetric flow rate: 5.13 m³/h - 951.57 m³/h
Process temperature: -18 °C - 121 °C
Process pressure: 16.5, 41 bar
The ST75 Series thermal flow meters are a compact, low cost solution for accurate, repeatable direct mass flow measurement of air and gases. These in-line (spool-piece) style flow ...
FCI Fluid Components International

Volumetric flow rate: 0.1667 l/min - 23.75 l/min
Process temperature: -40 °C - 454 °C
Process pressure: 70, 10 bar
... HART, Foundation Fieldbus, PROFIBUS PA, PROFIBUS DP, or Modbus, ST80 has you covered. Then for local display, the ST80’s graphical, backlit LCD is unmatched in showing what’s happening ...
FCI Fluid Components International

Volumetric flow rate: 0 m³/h - 244,290.2 m³/h
Process temperature: -20 °C - 120 °C
Process pressure: 1.6, 1, 0.6 MPa
The NMG-Series electromagnetic flowmeter is used to measure the volume flow of conductive liquids and slurries in closed pipes. The measuring flow rate is not affected by density, viscosity, ...

Volumetric flow rate: 1.6 m³/h - 3,125 m³/h
Process temperature: -40 °C - 70 °C
Process pressure: 1 bar - 10 bar
... reasonably priced, most accurate flow meter tailored for your applications. A flowmeter with base functionality, short delivery and a simple and clearly understandable documentation. EPD ...
FineTek Co., Ltd.

Process temperature: -20 °C - 60 °C
Precision: 2.5 %
... waves are dispersed is proportional to the flow rate of the liquid. Hence, the flow rate of the liquid is derived. EPU Clamp-On Ultrasonic Flowmeter No intrusion in the pipeline ...
FineTek Co., Ltd.

Process temperature: -156 °C - 60 °C
Process pressure: 10 bar
Repeatibility: 0.4 %
... measurement to get real flow signals, Elimination of bearing、Axial friction coefficient error and the leaf blade resistance error etc. Calculate the K value read. The company's flow test equipment, Testable ...
FineTek Co., Ltd.

Process temperature: -30 °C - 80 °C
... cycle operation for self-sufficient systems Flow metering at the highest technical level The NivuFlow 750 flow meter is the successor to the well-known OCM Pro CF. Compact dimensions ...
NIVUS GmbH

Process temperature: -20 °C - 70 °C
... as in low flow level circumstances -IoT-ready with global 4G connectivity for highest availability and digital services Hybrid Flow Measurement NivuFlow 7550 is a hybrid measurement system ...
NIVUS GmbH

Process temperature: -20 °C - 70 °C
... ambient conditions. The large graphic display permits quick and easy commissioning of the flow meter system. Due to the modular construction of our radar flow meter ...
NIVUS GmbH

Process temperature: 120 °C
Process pressure: 25 bar - 110 bar
FLOW MEASUREMENT FOR DENSE-PHASE CONVEYING Continuous solids mass flow measurement in dense-stream conveying and high levels of throughput Designed to measure solid flows ...

Process temperature: -40 °F - 350 °F
Precision: 1 %
Repeatibility: 0.2 %
The Dynasonics® DXN Portable Hybrid Ultrasonic flow meter is a powerful tool used for troubleshooting flow issues, whether you want to quickly verify the flow reading ...
Badger Meter

Process temperature: -40 °C - 120 °C
Process pressure: 0 MPa - 5 MPa
Repeatibility: 0.25 %
The S453 Compressed Air Flow Meter is specifically designed for heavy-duty and explosive (Ex) environments, providing precise and reliable thermal mass flow measurements for your industrial ...
SUTO iTEC GmbH

... compressed air flow meter is designed to be easy to use, affordable and it's offering a wide measurement range. This makes it easy for you to choose the right flow meter, ...
SUTO iTEC GmbH

... analog and pulse output to read out the flow and the total consumption. Alternatively a MODBUS RTU interface can be used to access all measured values via the digital interface. Various settings such ...
SUTO iTEC GmbH

AI.FFsonic MODEL Flow measurement at fixed transit time Speed range: max. ± 32m / s - Views: instantaneous flow, totalizer (volume) Outputs: 4 ÷ 20mA + 1 open collector + 1 relay Digital output RS 485 ...
ASIT ITALIA

Process temperature: 0 °C - 75 °C
Precision: 1 %
... ULTRASONIC FLOW AND TEMPERATURE METER Pipe sizes: DN 15, 20, 25, 32, 40 Piping Materials: Metals, PVC, PP or PVDF Types of Liquids: Water and other liquids such as Oil, Diesel Temp. range: 0..+75°C Output: ...
ASIT ITALIA

Process temperature: -30 °C - 160 °C
Precision: 1 %
... English, Italian and other languages can be customized Large LCD display: possible to view the instantaneous flow, velocity of the accumulated flow (positive, negative and net), operating status. Integrated ...
ASIT ITALIA

Process temperature: 0 °C - 60 °C
Process pressure: 0 bar - 10 bar
Precision: 2 %
... VPFlowScope M can be installed under pressure and measures (bi-directional) flow, pressure, temperature, and total flow simultaneously. The flow meter is an all-in-one ...
VPInstruments

Volumetric flow rate: 0 m³/h - 1,000 m³/h
Process temperature: 0 °C - 60 °C
Process pressure: 0 Pa - 3,500,000 Pa
... consumption of machines, cost allocation, and pressure loss monitoring. It measures (bi-directional) mass flow, temperature, pressure, and total flow which is key data for point of use ...
VPInstruments

Volumetric flow rate: 2.2 l/min - 50 l/min
Process temperature: 20 °C - 32 °C
Process pressure: 0 bar - 10 bar
... Thermabridge™ technology, the VPFlowScope In-line can perform accurate flow measurements. The built-in display will show the actual and total flow, and the Modbus and analog 4 .. 20 mA ...
VPInstruments

Process temperature: -40 °C - 85 °C
Precision: 1 %
Repeatibility: 0.1 %
... Low power consumption enables operation using solar cells - Recognition of flow direction - Measuring range from +/- 0.10 to +/- 15 m/s (depending on the flow conditions) - Recognition ...
SOMMER Messtechnik GmbH

Process temperature: -40 °C - 85 °C
Precision: 1 %
Repeatibility: 0.1 %
The flow velocity sensor RG-30 has been designed for contact-free measurements of the surface flow velocity of rivers and channels by means of radar technology. Features and advantages - Maintenance ...
SOMMER Messtechnik GmbH

Process temperature: -40 °C - 85 °C
Precision: 1 %
... , it is the ideal choice for flow measurements in manholes of facilities and sewers. FEATURES AND ADVANTAGES Non-contact measurement, maintenance-free system Calculation of discharge by continuous ...
SOMMER Messtechnik GmbH

Features : Designed for industrial application. Air flow measurement up to 120 m/s. Resistant to high temperature, high pressure, dust, and corrosion. Sensor type : Pt20 / Pt300(Air velocity) / Pt1000(Temp.) Measuring ...

Features : Suitable for clean air. Resistant to high pressure and high temperature. Sensor type : Thermal mass flow sensor Measuring range : 0 ... 90 m/s Output : 0 ... 20 mA / 4 ... 20 mA / 0 ... 1 V / 0 ... 5 V / ...
Your suggestions for improvement:
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining