Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 185 mm²
... for selected torsion applications conditionally suitable for drag chains versatile use in many industries, particularly in machine and plant construction PVC control and connection cable in alignment ...
HELUKABEL
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 50 mm²
... resistance - at 30 MHz, approx. 250 Ohm/km Minimum bending radius - flexible 10x Outer-Ø fixed 5x Outer-Ø Copper wire bare, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 Core ...
HELUKABEL
Nominal voltage: 450, 750 V
Temperature: -30 °C - 60 °C
Cross-section: 1 mm² - 500 mm²
heavy rubber connection cable oil resistant weather-resistant for medium mechanical stress Rubber connection cable, H07RN-F acc. to DIN VDE 0285-525-2-21 / DIN EN 50525-2-21; 07RN-F in alignment ...
HELUKABEL
Nominal voltage: 600 V
Temperature: -40 °C - 90 °C
Cross-section: 0.5 mm² - 120 mm²
... and connection cable acc. to UL-Std. 758 (AWM) Style 2587, CSA-Std. C22.2 No. 210 - AWM I/II A/B Test voltage core/core - 3000 V Breakdown voltage - 6000 V Minimum bending radius - flexible 7.5x Outer-Ø fixed 4x Outer-Ø ...
HELUKABEL
Temperature: -40 °C - 80 °C
Cross-section: 0.14 mm² - 1.5 mm²
... km Minimum bending radius - flexible 10x Outer-Ø fixed 5x Outer-Ø Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 Wire structure: 0.14 ...
HELUKABEL
Temperature: -30 °C - 80 °C
Cross-section: 0.14 mm² - 1.5 mm²
... km Minimum bending radius - flexible 10x Outer-Ø fixed 5x Outer-Ø Copper wire bare, 0.5 - 1.5 mm²: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 Wire structure: 0.14 ...
HELUKABEL
Nominal voltage: 350 V
Temperature: -40 °C - 70 °C
Cross-section: 0.25 mm² - 1 mm²
... Outer-Ø fixed 0.14 - 0.25 mm²: 4 x Outer-Ø 0.5 - 1 mm²: 5 x Outer-Ø Copper wire bare, extra finely stranded, 0.5 - 1 mm²: acc. to DIN VDE 0295 Class 6 / IEC 60228 Class 6 Wire structure: 0.14 ...
HELUKABEL
Nominal voltage: 350 V
Temperature: -40 °C - 70 °C
Cross-section: 0.14 mm² - 0.34 mm²
... at 30 MHz, approx. 250 Ohm/km Minimum bending radius - flexible 7.5x Outer-Ø fixed 4x Outer-Ø Copper wire bare, extra finely stranded Wire structure: 0.14 mm²: approx. 18 x 0.1 ...
HELUKABEL
Nominal voltage: 300, 500, 450, 750 V
Temperature: -55 °C - 145 °C
Cross-section: 0.25 mm² - 240 mm²
... insulation material Test voltage - 3500 V Minimum bending radius - flexible 8x Outer-Ø fixed 4x Outer-Ø Copper wire tinned, finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 ...
HELUKABEL
Nominal voltage: 300, 500 V
Temperature: -60 °C - 180 °C
Cross-section: 0.25 mm² - 185 mm²
Silicone single core finely stranded tinned wire increased temperature resistance Permissible operating temperature of the conductor - +180°C Test voltage - 2000 V Breakdown voltage - 5000 V Minimum ...
HELUKABEL
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining