Tripping current: 0 mA - 220 mA
... start/restart Start/restart interlock (RES) Static contactor monitoring (EDM) Stop function according to category Stop 0 Restart - Automatic Manual SIL - 3, IEC 61508 SILCL - 3, IEC/EN ...
Leuze electronic GmbH + Co. KG

Tripping current: 6 A
Trigger voltage: 24 V
unctions - Cross circuit monitoring One- or two-channel operation Start/restart interlock (RES) Time-delayed shutdown (STOP1) Restart - Automatic Manual SIL - 3, IEC 61508 SILCL - 3, IEC/EN ...
Leuze electronic GmbH + Co. KG

Tripping current: 0.5, 2 A
Trigger voltage: 24, 230 V
Application - Signal conversion of electronic safety outputs on potential-free relay contacts Restart - Automatic SIL - 3, IEC 61508 SILCL - 3, IEC/EN 62061 Performance Level ...
Leuze electronic GmbH + Co. KG

Tripping current: 12 mA
Trigger voltage: 24 V
... Transfer of diagnostic data via external fieldbus gateways Up to 300 function modules in a project SIL - 3, IEC 61508 SILCL - 3, IEC/EN 62061 Performance Level (PL) - Up to and including e, EN ...
Leuze electronic GmbH + Co. KG

Tripping current: 200 mA
Trigger voltage: 24 V
Application - Monitoring of safety functions Number of safe I/Os - 20 IN, 4 OUT Functions - Freely configurable safety main module Monitoring of all safe functions in machines and systems Transfer ...
Leuze electronic GmbH + Co. KG

Tripping current: 1,000 mA
Trigger voltage: 20 V - 28 V
... groups Start/restart interlock (RES), selectable Synchronization of controllers Restart - Automatic Manual SILCL - 2, IEC/EN 62061 Performance Level (PL) - d, EN ISO 13849-1 MTTFd - 44 years, EN ISO 13849-1 PFHD ...
Leuze electronic GmbH + Co. KG

Tripping current: 1,000 mA
Trigger voltage: 20 V - 28 V
... groups Start/restart interlock (RES), selectable Synchronization of controllers Restart - Automatic Manual SILCL - 2, IEC/EN 62061 Performance Level (PL) - d, EN ISO 13849-1 MTTFd - 38 years, EN ISO 13849-1 PFHD ...
Leuze electronic GmbH + Co. KG

Tripping current: 1,000 mA
Trigger voltage: 20 V - 28 V
... groups Start/restart interlock (RES), selectable Synchronization of controllers Restart - Automatic Manual SILCL - 2, IEC/EN 62061 Performance Level (PL) - d, EN ISO 13849-1 MTTFd - 38 years, EN ISO 13849-1 PFHD ...
Leuze electronic GmbH + Co. KG
Your suggestions for improvement:
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining