Primary voltage: 600 V
Our Bulletin 1411 Current Transformers (CTs) are low voltage transformers for various power measurement devices and applications, including protective relays, analog devices, transducers, and PowerMonitor™ ...
High-frequency current transformer for medium-voltage power cables The MCT 085 high-frequency current transformer (HFCT) is specifically designed for offline or online partial discharge (PD) measurement ...
Electric power: 0.125, 0.01, 0.015, 0.02 W
Primary current: 0.3 mA - 11.5 mA
Frequency: 400 Hz - 250,000 Hz
PICO surface mount units utilize materials and methods to withstand extreme temperatures (220º C) of vapor phase, I.R., and other reflow procedures without degradation of electrical or mechanical characteristics. Specifications MIL-PRF-27: ...
Pico Electronics
Electric power: 0.062 W - 0.75 W
Primary current: 0.5 A - 31.6 A
Frequency: 400 Hz - 100,000 Hz
PICO surface mount units utilize materials and methods to withstand extreme temperatures of vapor phase, I.R., and other reflow procedures without degradation of electrical or mechanical characteristics. Specifications MIL-PRF-27: ...
Pico Electronics
Electric power: 0.1 W - 0.6 W
Primary current: 0.4 mA - 30 mA
Frequency: 300 Hz - 75,000 Hz
PICO surface mount units utilize materials and methods to withstand extreme temperatures of vapor phase, I.R., and other reflow procedures without degradation of electrical or mechanical characteristics. Specifications MIL-PRF-27: ...
Pico Electronics
Electric power: 10 W - 50 W
P025 Planar Transformers (10W to 50W) Patented (U.S. PAT. 7,129,809) design with superior thermal management Rated power 10W-50W / Frequency range 300-500kHZ Surface mount (SMD) or through hole (TH) Topology - Forward ...
StandexMeder Electronics GmbH
Primary current: 20 A
The CSB is a custom current transformer that is manufactured by standex-Meder electronics. It is built with a primary and secondary winding whose controls are incorporated into a computer. This compact device is less ...
StandexMeder Electronics GmbH
Electric power: 50 W - 200 W
Rated power 50W-200W / Frequency range 175-300kHZ Surface mount (SMD) or through hole (TH) Topology - Half Bridge, Forward (w/active rest), Flyback Current rating max. SMD=50A, TH = +30% Isolation voltage pri-sec/pri-core 500-2,000VDC Soft ...
StandexMeder Electronics GmbH
Frequency: 45 Hz - 65 Hz
MRC022 TRMS Current Transformer with integrated Transducers hole Ø22 Selectable input 5÷30A with passive output 4-20 mA (2 wires technology) TRMS Multirange current transformers, with loop-powered ...
FRER
Primary current: 5 A - 8,000 A
Frequency: 50 Hz - 60 Hz
selfestinguishing thermoplastic material - UL94-V0 operating frequency - 50-60 Hz insulation reference voltage - 0,72 kV test voltage - 3kVx1'50 Hz insulation - dasse E protection degree - IP 20 continuous overcurrent - 1,2 In rated ...
FRER
Primary current: 800 A - 5,000 A
Frequency: 50 Hz - 60 Hz
selfestinguishing - thermoplastic material - UL94-V0 operating frequency - 50-60 Hz insulation reference voltage - 0,6 kV test voltage - 3 kV x 1'50 Hz insulation - dasse H protection degree - IP 00 protection degree with terminal ...
FRER
Primary current: 25 mA - 1,000 mA
Galvanic separation of drive and power circuit Voltage resistance up to 8 kV Ignition current up to 3 A Turns ratio up to 3:1 Ignition currents : 0.1 to 3 A Rise time : 0.3 to 2.3 µs Frequency : ≤ 40000 Hz Attenuation performance ...
Primary current: 40 A - 250 A
Secondary current: 5 A
Frequency: 40 Hz - 60 Hz
Measurement current transformers for currents from TAM series Modular LV analog current transformers, 2 modules width, from DIN bar for currents
Output power kVA: 50 kVA - 1,600 kVA
Primary voltage: 12 kV
Frequency: 50 Hz
... 50 ~1600kVA. The product puts the transformer body, high-voltage load switch, fuse and other components together in the transformer tank, and uses the insulating liquid of the transformer ...
Output power kVA: 630 kVA - 2,500 kVA
Primary voltage: 10, 35 kV
The ZGS-ZG series of combined photovoltaic transformers is a series of products developed by Tianan Electric to meet the needs of domestic and foreign users in photovoltaic power generation projects. It is the earliest ...
Output power kVA: 800 kVA - 3,400 kVA
Primary voltage: 35, 10 kV
The ZGS-ZF series wind power combined transformer is a series of products developed by Tianan Electric to meet the needs of wind power projects of domestic and foreign users. It is the earliest manufacturer of similar ...
TAB1- closed current transformers /5A TAB1: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting ...
TAB2 - closed current transformers /5A TAB2: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting ...
TAB3 - closed current transformers /5A TAB3: Closed version current transformer for low voltage systems Advantages of purchasing: Secondary with double faston 6.3 x 0.8 mm Possibility of inserting ...
... to give a signal, if the AC current exceeds a preselected setpoint. The setpoint is adjusted on a potentiometer on the transformer. 2. Current converters. These units converts the primary AC current to a standard 4-20 ...
Primary voltage: 0 V - 10 V
Primary current: 60 A - 600 A
Secondary current: 0 A - 0 A
Current transformer and measuring transducer in one housing The current transformer measuring transducers of the SCMU series are suitable for measuring sinusoidal alternating currents. The input variable ...
Primary voltage: 230, 24 V
Primary current: 10 A - 600 A
Secondary current: 4 A - 20 A
The current transformer measuring transducers of the SMU/I series are suitable for measuring sinusoidal alternating currents. The input variable is galvanically isolated (5kV/1min), rectified (averaging) and converted ...
Output power kVA: 0.3 kVA
Primary voltage: 220 V
Secondary voltage: 12 V
Our 300VA Toroidal Transformer is the ideal solution for your power supply needs. With an output of 12V AC and a power rating of 300VA, this transformer offers reliable and stable performance in a compact ...
Output power kVA: 100 kVA - 20,000 kVA
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
... Compared to the existing EcoDesign Tier2 Transformers set by the European Community, EcoPlus2030 Transformers boast significantly reduced CO2 emissions and losses. Just like the olive tree, our EcoPlus2030 ...
Primary voltage: 1,000 V - 52,000 V
Secondary voltage: 200 V - 10,000 V
Frequency: 50 Hz - 60 Hz
Tesar offer a wide range of customized solutions for feeding Data Centres: • Transformers with K factor up to 20 (high harmonic content) • Electrostatic screen between primary and secondary • Simplified Busbars connection ...
The production of cast resin power transformers can be divided in: Standard Production, which includes distribution transformers with rated power up to 3.150 kVA and voltage insulation level up to ...
Output power kVA: 0.01 kVA
Primary current: 5 A
- Ratio x/5A - Accuracy class 0.5 and 0.2S Screw mounting
Electric power: 10 kVA
Primary voltage: 440 V
Secondary voltage: 220, 127 V
... - 220Y/127 Secondary Volts - Acme three phase low voltage distribution transformers are designed for industrial and commercial applications. All of Acme general purpose transformers are rated for 600 ...
... classification for the protection current transformer intended to operate the particular protection device concerned. In addition the classification of protection current transformers indicates accuracy ...
Crompton Instruments
Primary current: 100, 5 A
Applications Balanced systems: network analyzers, automatic power factor correction systems (PFCs) Features Connection terminal with cover (IP20) for universal connection, no fork needed Bus bar or din rail mounting, included complete ...
Primary voltage: 230 V - 400 V
Secondary voltage: 24 V - 230 V
General Data Rated input voltage 230 ‑ 400 Vac Rated output voltage 24 ‑ 230 Vac Rated power 63 ‑ 2500 VA Insulation class B Maximum ambient temperature 40 °C Efficiency up to 95 % Degree of protection IP 00 Advantages Very good switch‑on ...
Block Transformatoren-Elektronik
Primary current: 10, 25, 5 A
... a CTBC… measuring current transformer core and a CTUB103 electronic module, which can be combined to suit the application. The measuring current transformers can be used in DC, AC and 3(N)AC systems ...
Primary current: 5 A - 450 A
Current transformer with built-in transducers ø 35mm Primary current field-selectable 9 programmable ranges Output 0..,20mA - 4..,20mA - 0...10V d.c. 4-wire technology, a.c. auxiliary supply
Split-Core Current Transformers Split-Core Current Transformers (CTs) are designed for applications where it is difficult or uneconomical to open the primary conductor to install a solid-core-type current ...
Electric power: 0.01 kVA - 31.5 kVA
The TR 21 CONTROL Transformers is a control and safety or seclude single-phase transformers. This device employs the principle of mutual induction to proselytize variations of current in a primary circuit ...
DF ELECTRIC
Primary current: 5 A - 1,000 A
- Donut and Terminal Style that Reduce High AC Current Signals to 5 AC Amperes - Model 186 Reduces High AC Current Signals to 10 AC Volts
Primary current: 0 mA - 2.5 mA
Characteristics:Combined voltage current transformer. Power to be measured works with current–limiting resistance. Adopt permalloy core, epoxy resin encapsulated, PCB welding, mounting height 14mm. Application: for voltage ...
YHDC Dechang Electric
This linear current transformer series, allow to obtain an AC or DC voltage on output without other transducer. This solution reduce the cost and space of the installation. Mechanical dimension and primary current ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining